ASTM D1171 PDF

Buy ASTM D R TEST METHOD FOR RUBBER DETERIORATION – SURFACE OZONE CRACKING OUTDOORS OR. D UltraLife Specimen Mold. UltraLife Specimen Molds by CCSi. CCSi UltraLife molds are designed, engineered, and manufactured to produce high quality. D Standard Test Method ASTM Standard Test Method for Rubber Deterioration-Surface Ozone Cracking Outdoors or Chamber (Triangular Specimens).

Author: Tuzil Moogusho
Country: Martinique
Language: English (Spanish)
Genre: Literature
Published (Last): 17 December 2009
Pages: 151
PDF File Size: 12.68 Mb
ePub File Size: 19.26 Mb
ISBN: 677-8-93009-945-2
Downloads: 98368
Price: Free* [*Free Regsitration Required]
Uploader: Dagami

ASTM D1171 – 16E1

Large triangular pry slots are located at the corners, opposite the cam-action hinges. MET listed products are also sold in every major retail stores throughout the United States and Canada. MET Laboratories, Inc aetm established in and has become a global service leader for product approvals and regulatory certification of electrical products in Baltimore, MD.

Please Request a Quotation for current pricing and delivery.

Whether you are a rubber component manufacturer, or you manufacture products with rubber components, we help you understand the ability of your product to withstand weathering or atmosphere exposure to ensure the quality of materials and achieve compliance to ozone deterioration standards, such as ASTM D The durable, hard chrome finish resists the corrosive and adhesive effects of most compounds, greatly improving overall durability and ease of maintenance.

The handles are ergonomically positioned to ease placement and removal from the heated laboratory press. The mold cavities are expertly honed and hand polished, after which the mold is industrial chrome plated.

Contact Us for a Service Quote. D UltraLife Specimen Mold. This also allows the overflow recesses to be deeper, reducing problems associated overfill. The handles are manufactured from stainless steel a chromium – nickel austenitic alloy and contain integral support pins. The CCSi UltraLife mold platens are thicker than standard molds, providing superior heat and pressure distribution, as well as extending the mold’s useful life by resisting distortion.

TOP 10 Related  BS EN ISO 14731 PDF

MET Labs is a service leader and trusted provider of product testing and regulatory certification of electrical products for leading brands and companies in the United States, Europe and worldwide. InMET broke the UL monopoly for product safety testing and certification in the United States and is approved to certify products in over UL standard categories. The NRTL mark is required under federal law for products used in workplaces in all 50 states.

Ozone Resistance Testing – MET Laboratories, Inc.

MET can simultaneously perform Environmental stress, Physical stress, Extreme climatic, and Chemical exposure testing to help you maximize testing accuracy and ensure product performance during exposure demanding environmental effects. This allows the handles to rotate, which facilitates opening the mold. These further facilitate mold opening and reduce the occurrence of cavity damage from improperly positioned tools.

Our Ozone testing capabilities and custom testing solutions utilize the latest technology and automation software to help you avoid premature product failure, ensure product durability, and validate the physical integrity and performance of your polymer products for faster time-to-market. The platens are positively positioned with precision guide pins and receivers Ozone Resistance Testing Helping you verify the integrity, reliability, and performance of your polymer, silicon, or elastomer products to maximize product durability and lifespan.

Ozone Resistance Testing Our Ozone testing capabilities and custom testing solutions utilize the latest technology ensuring product safety. Degradation can cause surface crazing, deep cracking causing significant weakening of a material, or complete fracture in polymers when products are subject to static or dynamic operational stresses, or residual surface stressing.

TOP 10 Related  CHRONOBIOLOGY BIOLOGICAL TIMEKEEPING PDF

CCSi UltraLife molds are designed, engineered, and manufactured to produce high quality specimens, over an extended service life!

Precision grinding ensures a parallel surface profile of the platens and CNC machining provides ultra-close dimensional tolerances, while the honing and polishing processes guarantee smooth, true specimen cavities. Get A Quote Today.

ASTM D Specimen Molds for Ozone Cracking Test

This test is not applicable to materials ordinarily classed as hard rubber, but is adaptable to molded or extruded soft rubber materials and sponge rubber for use in window weatherstripping as well as similar automotive applications. Ozone is a chemical compound found naturally in the atmosphere in low concentrations and is also generated by electrical or electromagnetic disturbances in contained spaces.

This uneven application of pressure may cause excessive overfill, or cavity voids.

CCSi UltraLife molds feature a unique cam-action hinge design which improves the critical distribution of pressure. English China Korea Taiwan. With our single-source testing solutions, ozone resistance testing can be bundled with a number d11171 other performance standards, like Highly Accelerated Life Ast HALTto give you a complete picture of the durability of your products. Ozone accelerates deterioration of rubber and plastic compounds, especially in environments that place physical stress on the compounds.